ADVICE

Use Cone Beam CT for GAE

  • Use cone beam CT intra-procedurally to identify target vessels for GAE; it improves anatomical visualization.
  • Despite initial extra time, it can speed catheterization and increase procedure quality.
INSIGHT

Embolize Multiple Abnormal Vessels

  • Embolizing more than one abnormal genicular vessel may yield better patient outcomes.
  • However, the ideal number and which vessels remain uncertain and need further study.
ADVICE

Optimize Embolic Particle Size

  • Use embolic particles sized between 100 and 250 microns for safety and efficacy.
  • Avoid particles smaller than 100 microns to reduce risk of nerve complications.